Switch Operating Temperature Symbol
An operating temperature of switches is represented by the lower temperature value preceding the letter of "T", and the higher temperature value is following the letter "T" which that switch operates.
Read more...


more articles...

Sales Contact
an image
ST Technology

Email: info@s-ttechnology.com

Phone: +(60) 4-588 4049
Fax: +(60) 4-587 4058
Switch Operating Temperature Symbol (Date: 2014-03-03)

An operating temperature of switches is represented by the lower temperature value preceding the letter of "T", and the higher temperature value is following the letter "T" which that switch indicated. If there is no value of lower temperature, the lower temperature is means to 0°C.

switch_t85_operating_temperature

Examples:

  1. T125 - Operating Temperature is 0°C to 125°C
  2.  25T85 -  Operating Temperature is -25°C to 85°C
  3. T85/55 - Store or unload Temperature is  0°C to 85°C, Machanical Operating Temperature is  0°C to 55°C.

Remarks: If there is no marking of temperature, means the Operating Temperature is  0°C to 55°C.